Skip to content

UC-002 Steps — Cable Cut via Rotation (BeTen+ / BeMini)

1) Verify prerequisites

  1. Confirm use case: UC-002.
  2. Confirm device model is BeTen+ or BeMini.
  3. Confirm firmware meets approved minimum:
  4. BeTen+: 4.2.26
  5. BeMini: 3.3.71
  6. Confirm motion/rotation detection capabilities are available.

2) Configure core rule

  1. Enable Rotation feature.
  2. Turn ON Rotation Counter.
  3. Set interval behavior by mode:
  4. Timer mode: Rotation interval must match Schedule Update.
  5. Motion (with Trips) mode: set a dedicated Rotation Interval = 0 or 60..86400 seconds (recommended 900 = 15 min).

3) Save/activate

  • If UI shows "No saved configuration available.", rule is Inactive.
  • Click Save.
  • Verify state becomes Active.

4) Configure software alerts and Push route JSON

  1. Create alert rule named Cable Cut.
  2. Ensure alert is visible in portal channel.
  3. In Push service route JSON, include:
  4. "aux5": "$$aux5"
  5. "aux6": "$$aux6"
  6. "fn_event": "$$cablemonitor"
  7. fn_event logic is implemented per below:
  8. If (current aux5 != previous aux5) OR (current aux6 != previous aux6) → $$cablemonitor = "Cable Down"
  9. Else → $$cablemonitor = ""
  10. (Optional) tag asset/device with CableCut.

5) Validate behavior

  1. Run a controlled simulation of cable-cut rotation condition.
  2. Confirm fn_event publishes Cable Down when aux5/aux6 changes.
  3. Confirm alert triggers with expected metadata.
  4. Verify no false positives under normal movement during observation window.