UC-001 Steps — BeSol+/BeWired+ Gateway and BeTen+ (as BeTag BLE beacon)
1) Verify prerequisites
- Confirm use case: UC-001.
- Confirm gateway is one of:
- BeSol+ (B4-MIOT-MR BSP), or
- BeWired+ (B4-MIOT-MR BTW).
- Confirm gateway firmware is >= 4.3.12.
- Confirm endpoint is BeTen+ (as BeTag / BLE beacon) with firmware >= 4.2.28.
- Confirm endpoint BLE Advertising = ON.
2) Configure Gateway (active parameters only)
Set exactly:
- Inactive Interval = 60 sec (allowed 30..86400, step 30)
- Scan Duration = 10 sec (allowed 5..600, step 5)
- Scan Window = 50 ms (allowed 1..40960)
- Manufacture ID = BeWhere (0x0277) (Default)
- RSSI Filter = Disabled (no dBm value)
3) Keep remaining fields as locked/optional
- Scan Method: locked at
2(all beacons) - Payload Mask: optional (
255) - Disable sensor: optional (
false)
4) Configure software-side mapping
- Add a Sensor Tag device in software.
- Ensure Sensor Tag MAC matches BTB device MAC Address.
- Assign user tag: Sensor.
5) Conditional Geotab mode (only when required)
If sensor data must be sent to Geotab as Measurement for Gateway: 1. Enable Third Party Integration. 2. Ensure Serial Number (External) matches Gateway External Serial Number. 3. Add ProbeZoneX, where X = Measurement ID (1..4).
6) Activate configuration
- If UI shows "No saved configuration available.", configuration is Inactive.
- Click Save to persist settings.
- After save, state must be Active.
7) Validation checks (must pass)
- Active parameters meet allowed ranges and step constraints.
- Inactive/active state is correctly identified before/after Save.
- Sensor Tag exists, MAC mapping is correct, and user tag is
Sensor. - Geotab conditions are satisfied when Geotab mode is used:
- Third Party Integration ON
- External serial match
- ProbeZoneX set for Measurement ID 1..4